| Brand Name: | WELLMAN | 
| Model Number: | X6800 | 
| MOQ: | 1 | 
| Payment Terms: | T/T | 
| X-ray Source | ||
|---|---|---|
| Type | Closed, microfocus | |
| Max tube voltage | 90kV | |
| Max tube current | 200μA | |
| Focal spot size | 5μm | |
| Function | Auto preheat | |
| Flat Panel Detector | ||
| Effective area | 130mm*130mm | |
| Pixel size | 85μm | |
| Resolution | 1536*1536 | |
| Frame rate | 20fps | |
| Tiltable angle | 60° | |
| Table Specifications | ||
| Size | 530mm*530mm | |
| Detectable area | 500mm*500mm | |
| Max load | 10kg | |
| System Specifications | ||
| Magnification | Geometry | 200X | 
| System | 1500X | |
| Inspection speed | Max 3.0s/point | |
| Dimensions | 1360mm (L)*1365mm (W)*1730mm(H) | |
| Weight | 1200kg | |
| Power supply | AC110-220V 50/60HZ | |
| Max power | 1500W | |
| Industrial PC | I5 CPU, 8G RAM, 500GB SSD | |
| Displayer | 24"HDMI LCD | |
| Safety Features | ||
| Radiation leakage | No leakage (≤1μSv/h, international standard) | |
| Lead glass observation window | Transparent lead glass shields radiation while allowing internal observation | |
| Window and back door safety interlock | X-ray tube powers off immediately when opened | |
| Electromagnetic safety switch | Locks when X-ray is active | |
| Emergency stop | Located near operation position for immediate power off | |
| Tube protection | Software prevents leaving without proper X-ray tube closure | |
| Function Module | Description | 
|---|---|
| Operation | Complete control via keyboard and mouse | 
| X-ray tube control | Mouse-click activation with real-time voltage/current display and adjustment | 
| Status bar | Visual indication of interlock, pre-heat, and X-ray status | 
| Image effect adjustment | Customizable brightness, contrast and gain settings | 
| Product list | Save and recall inspection parameters for efficient repeat inspections | 
| Navigation window | Click-to-position table movement with on-screen display | 
| Motion axis status | Real-time coordinate display | 
| Inspection result | Organized display of measurement results (voids rate, distance, area, etc.) | 
| Speed control | Adjustable axis movement speed (slow/normal/fast) | 
| Voids rate measurement | Automatic calculation with NG/OK color indication | 
| Parameters adjustment | Customizable grayscale threshold, pixel, contrast, and size filtering | 
| Add voids manually | Polygon or freehand void marking capability | 
| Save parameters | Store settings for future product inspections | 
| Distance measurement | Point-to-point and vertical distance calculation | 
| Distance rate | Percentage ratio measurement (ideal for through-hole soldering) | 
| Angle measurement | Precise angle calculation between defined points | 
| Radius measurement | Circle determination and measurement (circumference, area, radius) | 
| Perimeter measurement | Square component measurement (length, width, area) |