Harga bagus  on line

detail produk

Rumah > Produk >
Sumber Sinar-X Hamamatsu
>
Hamamatsu X-Ray Source: NDT/X-ray CT for Electronic Components & PCB

Hamamatsu X-Ray Source: NDT/X-ray CT for Electronic Components & PCB

Nama Merek: HAMAMATSU
Nomor Model: L11831-01
Moq: 1
Ketentuan Pembayaran: T/T
Informasi Detail
Tempat asal:
JEPANG
Nama merek:
Hamamatsu
Tempat asal:
JEPANG
Kemasan rincian:
karton
Bahan Sasaran:
Tungsten
Komunikasi:
Antarmuka: RS-232C (konektor D-sub 9-pin)
Menyoroti:

Hamamatsu X-ray source for NDT

,

X-ray CT for electronic components

,

PCB inspection X-ray source

Deskripsi produk
Hamamatsu X-Ray Source: NDT/X-ray CT for Electronic Components & PCB

90 kV MICROFOCUS X-RAY SOURCE

Applications
  • Non-destructive Inspection
  • X-ray CT
  • In-line X-ray Inspection
Applicable Objects
  • Electronic components
  • Printed circuit boards
  • Plastic components
  • Metal components
Features
  • Focal Spot Size: 15 μm (at 90kV)
  • The focal spot of 5 μm of the sealed type X-ray tube enables sharp and clear X-ray images even at high magnification
  • Easy Handling: Fully operable from an external PC
  • Serial Port Control (RS-232C): One package of a sealed type X-ray tube, a high-voltage power supply and a control function
Tube Current Operational Range
Hamamatsu X-Ray Source: NDT/X-ray CT for Electronic Components & PCB 0
Dimensional Outline
Hamamatsu X-Ray Source: NDT/X-ray CT for Electronic Components & PCB 1
Specifications
GENERAL
Parameter Description/Value Unit
Input Voltage(DC) +24 V
Power Consumption(Max.) 96 W
Operating Ambient Temperature +10 to+40
Storage Temperature 0 to +50
Operating and Storage Humidity Below 85(No Condensation) %
Weight Approx.10 kg
Conformance Standards CE(EMC:IEC61326-1,Group1.Class A)
Operation Continuous
High Voltage Power Supply Built-in
X-RAY TUBE
Parameter Description/Value Unit
X-ray Tube Sealed Type
X-ray Tube Cooling Method Convection Cooling __
X-ray Tube Window Matenal/Thickness Berylium/150 μm
Target Material Tungsten
Tube Voltage OperationalRange 20 to 90 kV
Tube Current Operational Range① 10 to 200 (8 WMax.) μA
Maximum Output 8 W
X-ray Focal Spot Size 7(5μm at 4W) μm
X-ray Beam Angle (Coned) 39 degrees
Focus to Object Distance (FOD) 9.5 mm
X-RAY CONTROL PART
Parameter Description Unit
Function Tube Voltage and Tube Current Preset /Auto Warm-up
Protection Interlock
External Control RS-232C
Applicable OS Windows2000 Professional,XP Professional __
Computer Operating Conditions CPU:IntelPentium or Higher,Memory:64MB or More