| Nama Merek: | WELLMAN |
| Nomor Model: | X6800 |
| Moq: | 1 |
| Ketentuan Pembayaran: | T/T |
| X-ray source | ||
|---|---|---|
| Type | Closed, microfocus | |
| Max tube voltage | 90kV | |
| Max tube current | 200μA | |
| Focal spot size | 5μm | |
| Function | Auto preheat | |
| Flat panel detector | ||
| Effective area | 130mm*130mm | |
| Pixel size | 85μm | |
| Resolution | 1536*1536 | |
| Frame rate | 20fps | |
| Tiltable angle | 60° | |
| Table | ||
| Size | 530mm*530mm | |
| Detectable area | 500mm*500mm | |
| Max load | 10kg | |
| Equipment | ||
| Magnification | Geometry 200X | System 1500X |
| Inspection speed | Max 3.0s/point | |
| Dimensions | 1360mm (L)*1365mm (W)*1730mm(H) | |
| Weight | 1200kg | |
| Power supply | AC110-220V 50/60HZ | |
| Max power | 1500W | |
| Industrial PC | I5 CPU,8G RAM,500GB SSD | |
| Displayer | 24"HDMI LCD | |
| Safety | ||
| Radiation leakage | No leakage, international standard:≤1μSv/h | |
| Lead glass observation window | Transparent lead glass window shields radiation to observe the inner status. | |
| Window and back door safety interlock | Once users open the window or back door, X-ray tube will power off immediately. When the window or back door is open, users can't turn on the X-ray. | |
| Electromagnetic safety switch | Lock once the X-ray is on, users can't open the observation window. | |
| Emergency stop | Next to the operation position, press to power off | |
| Tube protection | User can't leave the software to if you don't close the X-ray tube. | |
| Function module | Operation |
|---|---|
| Keyboard and mouse can finish all operations | |
| X-ray tube control | Using mouse to click the X button can turn on or off the X-ray. The real-time tube voltage and current value will display beside, users can click up and down button, or drag the slider, or type to adjust. |
| Status bar | Indicates the interlock status, pre-heat status, and X-ray status by flashing alternately red and green. |
| Image effect adjustment | The brightness, contrast and gain of the image can be adjusted freely to achieve a satisfactory result. |
| Product list | Users can save the inspection parameters such as Z-axis position, brightness, contrast and gain, and can directly call the parameters when inspecting the same product, to improve the inspection efficiency. |
| Navigation window | After the camera takes a photo of the table, click anywhere in the photo, the table will move to the place you click and display on the screen. |
| Motion axis status | Display real-time coordinates. |
| Inspection result | The measurement results (voids rate, distance, area, etc., set by users) display in order. |
| Speed control | The movement speed of each axis can be adjusted to slow, normal and fast. |
| Voids rate measurement |
Automatic calculation
Click on two points to determine a rectangle. The software automatically finds and measures the edge of the solder ball in the rectangle, the pad and the internal voids, and can get the data of the voids rate, the area of the solder ball, the circumference, the biggest voids rate, the length and the width, and indicates NG or OK by red and green. Parameters adjustment
Users can adjust the grayscale threshold, pixel, contrast, size filtering and other parameters to get accurate results of automatic calculation. Add voids manually
Users can draw a polygon or a free figure and calculate it as a void into the void rate. Save parameters
Users can save parameters such as grayscale threshold, pixel, contrast, size filtering and other parameters, and can directly call the parameters when detecting the same product, to improve the detection efficiency. |
| Other measurement function |
Distance
Click the A and B points to set as the baseline, then click the C point to measure the vertical distance from the C point to the baseline. Distance rate
It is mostly used to measure the soldering rate of the through-hole. Set one more point "D" than the distance. Divide the vertical distance from the D point to baseline by the vertical distance of the C point, to obtain the percentage ratio of the vertical distance of D to C. Angle
Click the A and B points to set as the baseline, then click the C point to measure the angle between the BA and BC rays. Radius
It is mostly used to measure round components such as solder balls. Click three points to determine a circle and measure the circumference, area and radius. Perimeter
It is mostly used to measure square components, click two points to determine a square, measure the length, width and area. |