X Ray Counter Offering Microfocus X Ray Source with 90 Kilovolt Maximum Tube Voltage

X Ray Counter Offering Microfocus X Ray Source with 90 Kilovolt Maximum Tube Voltage

Marchio: WELLMAN
Numero modello: X6800
Moq: 1
Termini di pagamento: T/T
Informazioni Dettagliate
Luogo di origine:
Cina
Certificazione:
CE FDA
Tipo:
Chiuso, microfuoco
Zona effettiva:
130 mm*130 mm
Dimensione pixel:
85 μm
Risoluzione:
1536*1536
Dimensioni:
1360mm (L) * 1365mm (W) * 1730mm (H)
Evidenziare:

microfocus X ray counter

,

90 kilovolt X ray source

,

X ray tube voltage counter

Descrizione del prodotto
X Ray Counter Offering Microfocus X Ray Source with 90 Kilovolt Maximum Tube Voltage
Product Overview
Microfocus X-Ray Inspection System X6800
Key Advantages
  • Closed type X-ray tube with more than 10,000 hours lifetime, maintenance-free
  • New generation 5" HD digital flat panel detector (FPD)
  • FPD can tilt 60° without sacrificing magnification
  • Automatic navigation window - table moves to clicked position
  • 530×530mm table with 10KG load capacity
  • Speed adjustable 5-axis linkage system
  • Programmable inspection procedures for automated batch inspection
  • Easy to operate with only 2 hours training required
Hardware Specifications
Component Parameter Specification
X-ray Source Type Closed, microfocus
Max Tube Voltage 90kV
Max Tube Current 200μA
Focal Spot Size 5μm
Flat Panel Detector Effective Area 130mm×130mm
Pixel Size 85μm
Resolution 1536×1536
Frame Rate 20fps
Tiltable Angle 60°
Table Size 530mm×530mm
Detectable Area 500mm×500mm
Max Load 10kg
Equipment Magnification Geometry 200X | System 1500X
Inspection Speed Max 3.0s/point
Dimensions 1360mm (L)×1365mm (W)×1730mm(H)
Weight 1200kg
Power Supply AC110-220V 50/60HZ
Max Power 1500W
Industrial PC I5 CPU, 8G RAM, 500GB SSD
Safety Features Radiation Leakage No leakage, international standard: ≤1μSv/h
Lead Glass Observation Window Transparent lead glass window shields radiation to observe inner status
Window and Back Door Safety Interlock X-ray tube powers off immediately when window or back door is opened
Electromagnetic Safety Switch Locks when X-ray is on, preventing window opening
Emergency Stop Located next to operation position for immediate power off
Tube Protection Software prevents leaving without closing X-ray tube
Software Capabilities
Operation Interface
Keyboard and mouse complete all operations
X-ray Tube Control
Mouse-click operation with real-time voltage/current display and adjustment
Status Monitoring
Visual indicators for interlock, pre-heat, and X-ray status
Image Enhancement
Adjustable brightness, contrast and gain for optimal results
Product Database
Save and recall inspection parameters for efficiency
Navigation System
Click-to-move table positioning with camera guidance
Measurement Functions
Voids rate, distance, angle, radius, perimeter, and area calculations
Speed Control
Adjustable movement speed for each axis (slow, normal, fast)
Working Principle
X Ray Counter Offering Microfocus X Ray Source with 90 Kilovolt Maximum Tube Voltage 0
Application Examples
X Ray Counter Offering Microfocus X Ray Source with 90 Kilovolt Maximum Tube Voltage 1 X Ray Counter Offering Microfocus X Ray Source with 90 Kilovolt Maximum Tube Voltage 2