| ブランド名: | WELLMAN |
| モデル番号: | x8800 |
| 支払い条件: | T/T |
| Focal spot size | 1μm |
| Type | Open, microfocus |
| Max tube voltage | 160kV |
| Max tube current | 500μA |
| Target power | 15W |
| Tube power | 65W |
| Tiltable angle | 60° |
| Rotation angle | 360° |
| Pixel size | 49.5μm |
| Resolution | 1536×1536 |
| Frame rate | 20fps |
| Max load | 10kg |
| Size | 400mm×400mm |
| Detectable area | 400mm×400mm |
| Geometry Magnification | 2500X |
| Inspection speed | Max 3.0s/point |
| Dimensions | 1550mm (L) × 1600mm (W) × 1700mm (H) |
| Weight | 1800kg |
| Power supply | AC110-220V 50/60HZ |
| Max power | 1800W |
| Industrial PC | I7 CPU, 16G RAM, 240GB SSD+1TB HDD |
| Displayer | 24" HDMI LCD |
| Radiation leakage | No leakage |
| Lead glass observation window | Transparent lead glass window shields radiation to observe the inner status |
| Window and back door safety interlock | Once users open the window or back door, X-ray tube will power off immediately |
| Electromagnetic safety switch | Lock once the X-ray is on, users can't open the observation window |
| Emergency stop | Next to the operation position, press to power off |
| Tube protection | User can't leave the software if you don't close the X-ray tube |
| Operation | Keyboard and mouse can finish all operations |
| X-ray tube control | Using mouse to click the X button can turn on or off the X-ray |
| Status bar | Indicates the interlock status, pre-heat status, and X-ray status |
| Image effect adjustment | Brightness, contrast and gain adjustable for optimal results |
| Product list | Save and recall inspection parameters for efficiency |
| Navigation window | Click anywhere in the photo to move table to position |
| Motion axis status | Display real-time coordinates |
| Inspection result | Measurement results display in order with NG/OK indicators |
| Speed control | Movement speed adjustable to slow, normal and fast |
| Automatic calculation | Click two points to determine rectangle for automatic solder ball analysis |
| Parameters adjustment | Adjust grayscale threshold, pixel, contrast, and size filtering |
| Add voids manually | Draw polygons or free figures to calculate as voids |
| Save parameters | Save and recall parameters for consistent detection efficiency |
| Distance | Measure vertical distance from point to baseline |
| Distance rate | Calculate percentage ratio for through-hole soldering rate measurement |
| Angle | Measure angle between rays |
| Radius | Measure round components including circumference, area and radius |
| Perimeter | Measure square components including length, width and area |
| Manual setting | Set any positions as inspection points for automated inspection |
| Array | Automatically inspect regular inspection points with row/column setup |
| Automatic identification | Software automatically identifies positions with obvious features |