قیمت خوب  آنلاین

جزئیات محصولات

خونه > محصولات >
منبع اشعه ایکس هاماماتسو
>
Hamamatsu 5 um 90KV Microfocus and closed type X-ray Tubes with The longest lifetime overpass 10000 hours

Hamamatsu 5 um 90KV Microfocus and closed type X-ray Tubes with The longest lifetime overpass 10000 hours

نام تجاری: Hamamatsu
شماره مدل: 130 کیلو ولت
شرایط پرداخت: T/T
اطلاعات دقیق
محل منبع:
ژاپن
اندازه نقطه کانونی:
5 ام در 4 وات
دامنه ولتاژ لوله:
20 تا 90 کیلو ولت
جزئیات بسته بندی:
کارتن
توضیح محصول
Hamamatsu 5 µm 90KV Microfocus and Closed Type X-ray Tubes
Product Overview

High-performance microfocus X-ray tubes featuring the longest lifetime exceeding 10,000 hours, designed for precision non-destructive inspection applications.

Hamamatsu 5 um 90KV Microfocus and closed type X-ray Tubes with The longest lifetime overpass 10000 hours 0
Applications
  • Non-destructive inspection
  • X-ray CT scanning
Applicable Objects
  • Electronic components
  • Printed circuit boards
  • Plastic components
  • Metal components
Key Features
Focal Spot Size: 5 µm (at 4 W)
High Voltage: No cable connection required
Control Interface: External RS-232C
Power Output: Maximum 39 W
General Specifications
Parameter Description / Value Unit
Input Voltage (DC) +24 V
Power Consumption (Max.) 96 W
Operating Ambient Temperature +10 to +40 °C
Storage Temperature 0 to +50 °C
Operating and Storage Humidity Below 85 (No Condensation) %
Weight Approx. 10 kg
Conformance Standards CE(EMC: IEC 61326-1, Group1, Class A) -
Operation Continuous -
High Voltage Power Supply Built-in -
X-ray Tube Specifications
Parameter Description / Value Unit
X-ray Tube Sealed Type -
X-ray Tube Cooling Method Convection Cooling -
X-ray Tube Window Material / Thickness Beryllium / 150 µm
Target Material Tungsten -
Tube Voltage Operational Range 20 to 90 kV
Tube Current Operational Range 10 to 200 (8 W Max) μA
Maximum Output 8 W
X-ray Focal Spot Size 7 (5 µm at 4 W) µm
X-ray Beam Angle (Coned) 39 degrees
Focus to Object Distance (FDF) 9.5 mm
X-ray Control Specifications
Parameter Description / Value Unit
Function Tube Voltage and Tube Current Preset / Auto Warm-up -
Protection Interlock -
External Control RS-232C -
Applicable OS Windows 2000 Professional, XP Professional -
Computer Operating Conditions CPU: Intel Pentium or Higher, Memory: 64 MB or More -
Tube Current Operational Range
Hamamatsu 5 um 90KV Microfocus and closed type X-ray Tubes with The longest lifetime overpass 10000 hours 1
Dimensional Outline