| Nombre De La Marca: | WELLMAN |
| Número De Modelo: | Rayos X X-6800 |
| Términos De Pago: | T/T |
| X-ray Source | |
|---|---|
| Type | Closed, microfocus |
| Max Tube Voltage | 90kV (110kV, 130kV optional) |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm (4μm, 2μm optional) |
| Function | Auto preheat |
| Flat Panel Detector | |
| Effective Area | 130mm × 130mm |
| Pixel Size | 85μm |
| Resolution | 1536 × 1536 |
| Frame Rate | 20fps |
| Tiltable Angle | 60° |
| Table | |
| Size | 530mm × 530mm |
| Detectable Area | 500mm × 500mm |
| Max Load | 10kg |
| Equipment | |
| Magnification | Geometry 200X | System 1500X |
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1360mm (L) × 1365mm (W) × 1730mm (H) |
| Weight | 1200kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1500W |
| Industrial PC | I5 CPU, 8G RAM, 500GB SSD |
| Displayer | 24" HDMI LCD |
| Safety Features | |
| Radiation Leakage | No leakage, international standard: ≤1μSv/h |
| Lead Glass Observation Window | Transparent lead glass window shields radiation to observe the inner status |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or back door is opened |
| Electromagnetic Safety Switch | Locks observation window when X-ray is active |
| Emergency Stop | Located next to operation position for immediate power cutoff |
| Tube Protection | Software prevents leaving without closing X-ray tube |
| Function Module | Operation |
|---|---|
| Basic Controls | Complete operation via keyboard and mouse |
| X-ray Tube Control | Mouse-click activation with real-time voltage/current display and adjustment |
| Status Bar | Visual indication of interlock, pre-heat, and X-ray status |
| Image Effect Adjustment | Adjustable brightness, contrast and gain for optimal imaging |
| Product List | Save and recall inspection parameters for improved efficiency |
| Navigation Window | Click-to-move functionality for precise positioning |
| Motion Axis Status | Real-time coordinate display |
| Inspection Result | Organized display of measurement results with pass/fail indication |
| Speed Control | Adjustable movement speed for each axis |
| Voids Rate Measurement | Automatic calculation of voids rate, area, circumference, and defect identification |
| Parameter Adjustment | Customizable grayscale threshold, pixel, contrast, and size filtering |
| Manual Void Addition | Polygon or free-form drawing for custom void inclusion |
| Parameter Saving | Save and recall measurement parameters for consistent results |
| Distance Measurement | Point-to-baseline vertical distance calculation |
| Distance Rate | Percentage ratio measurement for through-hole soldering rate |
| Angle Measurement | Angle calculation between defined rays |
| Radius Measurement | Circle determination and measurement for round components |
| Perimeter Measurement | Length, width and area calculation for square components |
| Automatic Inspection | Manual point setting for automated inspection and image saving |
| Array Inspection | Automated inspection of regular grid patterns |
| Automatic Identification | Feature-based position recognition for automated measurement |