Hamamatsu X Ray Source 130 kV Microfocus X Ray Source with PC AT

Nombre De La Marca: HAMAMATSU
Número De Modelo: L9181-02
Moq: 1
Términos De Pago: T/T
Información Detallada
Lugar de origen:
Japón
Nombre de la marca:
Hamamatsu
Lugar de origen:
Japón
Detalles de empaquetado:
CAJA DE CARTÓN
Material objetivo:
Tungsteno
Método de comunicación:
Interfaz: RS-232C (conector sub-D de 9 pines)
Resaltar:

Hamamatsu microfocus X-ray source 130kV

,

PC AT compatible X-ray source

,

130kV microfocus X-ray tube

Descripción del Producto
Hamamatsu X Ray Source 130 kV Microfocus X Ray Source with PC AT
Product Overview

Hamamatsu X Ray Source 130 kV Microfocus X Ray Source L9181-02

Applicable Objects
  • Electronic component
  • Printed circuit board
  • Plastic component
  • Metal component
Control Software Specifications
Parameter Description Unit
Applicable PC PC/AT compatible --
Applicable OS Windows® XP, 7 --
Interface RS-232C --
Regulations and Standards
Parameter Description Unit
RoHS Directive EN 50581 Category 9 --
EMC IEC/EN 61326-1
Emission limits: CISPR 11 Group 1 Class A
Immunity requirements: Table 2
--
Technical Ratings
Parameter Description/Value Unit
Input voltage (DC) +24 (+2.4,-0) V
Power consumption Less than 120 W
Read output Continuous rating --
Operating ambient temperature +10 to +40
Storage ambient temperature 0 to +50
Operating and storage humidity 20 to 85 (No condensation) %
General Specifications
Parameter Description/Value Unit
X-ray tube voltage setting range 0 to 130 kV
X-ray tube current setting range 0 to 300 μA
X-ray tube voltage operational range 40 to 130 kV
X-ray tube current operational range 10 to 300 μA
Maximum output Small focus mode: 8 W
Middle focus mode: 16 W
Large focus mode: 39 W
W
X-ray focal spot size (Nominal value) Small focus mode: 8 (5μm at 4 W)
Middle focus mode: 20
Large focus mode: 40
μm
X-ray output window material/Thickness Beryllium/0.2 mm
X-ray beam angle Approx.45 degree
Focus to object distance (FOD) Approx.13 mm
Target material Tungsten --
Weight Approx.10.5 kg
Communication method Interface: RS-232C (9-pin D-sub connector) --
Important Notes

① See the graph of the X-ray tube voltage/current operation range.

② Reference value: With 50% of maximum X-ray emission.

③ This weight includes the accessories of approx. 0.25 kg.

④ The control software is provided as a sample software for the purpose of MFX operation. The performance of the software is not guaranteed.