| ชื่อแบรนด์: | WELLMAN |
| หมายเลขรุ่น: | เอ็กซ์เรย์ X8800 |
| เงื่อนไขการชำระเงิน: | ที/ที |
| Type | Open, microfocus |
|---|---|
| Maximum Tube Voltage | 160kV |
| Maximum Tube Current | 500μA |
| Target Power | 15W |
| Tube Power | 65W |
| Focal Spot Size | 1μm |
| Effective Area | 130mm×130mm |
|---|---|
| Pixel Size | 49.5μm |
| Resolution | 1536×1536 |
| Frame Rate | 20fps |
| Tiltable Angle | 60° |
| Rotation Angle | 360° |
| Size | 400mm×400mm |
|---|---|
| Detectable Area | 400mm×400mm |
| Maximum Load | 10kg |
| Geometry Magnification | 2500X |
|---|---|
| Inspection Speed | Maximum 3.0s/point |
| Dimensions | 1550mm (L) × 1600mm (W) × 1700mm (H) |
| Weight | 1800kg |
| Power Supply | AC110-220V 50/60HZ |
| Maximum Power | 1800W |
| Industrial PC | I7 CPU, 16G RAM, 240GB SSD+1TB HDD |
| Display | 24" HDMI LCD |
| Radiation Leakage | No leakage, international standard: ≤1μSv/h |
|---|---|
| Lead Glass Observation Window | Transparent lead glass shields radiation for internal status observation |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when opened; prevents X-ray activation when open |
| Electromagnetic Safety Switch | Locks when X-ray is active, preventing window opening |
| Emergency Stop | Located near operation position for immediate power cutoff |
| Tube Protection | Prevents software exit without closing X-ray tube |
| Function Module | Operation |
|---|---|
| X-ray Tube Control | Mouse-click activation with real-time voltage/current display and adjustment |
| Status Bar | Visual indication of interlock, pre-heat, and X-ray status |
| Image Effect Adjustment | Brightness, contrast and gain controls for optimal imaging |
| Product List | Save and recall inspection parameters for efficiency |
| Navigation Window | Click-to-move table positioning with camera guidance |
| Motion Axis Status | Real-time coordinate display |
| Inspection Result | Organized display of measurement data (voids rate, distance, area) |
| Speed Control | Adjustable movement speed for each axis (slow, normal, fast) |
| Feature | Description |
|---|---|
| Automatic Calculation | Rectangle-based solder ball analysis with automatic void detection and NG/OK indication |
| Parameters Adjustment | Customizable grayscale threshold, pixel, contrast, and size filtering |
| Manual Void Addition | Polygon or free-form drawing for custom void calculation |
| Parameter Saving | Store and recall detection parameters for consistent results |
| Function | Application |
|---|---|
| Distance | Vertical distance measurement from point to baseline |
| Distance Rate | Through-hole soldering rate calculation via percentage ratio |
| Angle | Angle measurement between defined rays |
| Radius | Circular component measurement (solder balls) for circumference, area, radius |
| Perimeter | Square component measurement for length, width, and area |
| Mode | Description |
|---|---|
| Manual Setting | Custom inspection point placement with automatic imaging |
| Array | Grid-based automatic inspection from minimal setup parameters |
| Automatic Identification | Feature-based position recognition with automated measurement and imaging |