| Function Module | Operation Details |
|---|---|
| X-ray Tube Control | Mouse-click X button to toggle X-ray on/off. Real-time display of tube voltage and current with adjustable settings via buttons, sliders, or direct input |
| Status Bar | Visual indication of interlock status, pre-heat status, and X-ray status via alternating red/green flashing |
| Image Effect Adjustment | Free adjustment of brightness, contrast, and gain for optimal image quality |
| Product List | Save inspection parameters (Z-axis position, brightness, contrast, gain) for efficient repeat inspections |
| Navigation Window | Camera captures table image - click anywhere to automatically move table to selected position |
| Motion Axis Status | Real-time coordinate display |
| Inspection Results | Organized display of measurement results including voids rate, distance, area, and user-defined parameters |
| Speed Control | Adjustable movement speed for each axis (slow, normal, fast) |
| Feature | Description |
|---|---|
| Automatic Calculation | Click two points to define rectangle - software automatically detects and measures solder ball edges, pads, and internal voids. Provides voids rate, solder ball area, circumference, maximum void rate, dimensions, and NG/OK status indication |
| Parameters Adjustment | Adjust grayscale threshold, pixel settings, contrast, size filtering for accurate automated calculations |
| Manual Void Addition | Draw polygons or free-form shapes to include as voids in rate calculations |
| Parameters Saving | Save grayscale threshold, pixel, contrast, size filtering parameters for efficient repeat inspections |
| Measurement Type | Application |
|---|---|
| Distance | Set baseline with points A and B, measure vertical distance from point C to baseline |
| Distance Rate | Measure through-hole soldering rate using points A, B, C, D - calculates percentage ratio of vertical distances |
| Angle | Set baseline with points A and B, measure angle between BA and BC rays |
| Radius | Measure round components (solder balls) using three points to determine circle - calculates circumference, area, radius |
| Perimeter | Measure square components using two points to determine square - calculates length, width, area |
| Mode | Functionality |
|---|---|
| Manual Setting | Set custom inspection positions - software automatically inspects and saves images |
| Array | For regular inspection points - set two points and row/column count for automated point-by-point inspection with image saving |
| Automatic Identification | Software automatically identifies positions with obvious features, performs measurements, and saves images |
| Brand | Japan Hamamatsu |
| Type | Closed, microfocus |
| Max Tube Voltage | 90KV |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm |
| Function | Auto preheat |
| Effective Area | 130mm × 130mm |
| Pixel Size | 85μm |
| Resolution | 1536 × 1536 |
| Frame Rate | 20fps |
| Tiltable Angle | ±45° |
| Rotation Angle | 360° |
| Table Size | 400mm × 400mm |
| Detectable Area | 400mm × 400mm |
| Max Load | 10kg |
| Magnification | Geometry 200X | System 1500X |
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1550mm(L) × 1600mm(W) × 1700mm(H) |
| Weight | 1800kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1800W |
| Industrial PC | 15 CPU, 8G RAM, 240GB SSD |
| Displayer | 24" HDMI LCD |
| Radiation Leakage | No leakage, meets international standard: ≤1μSv/h |
| Lead Glass Observation Window | Transparent lead glass shields radiation while allowing internal observation |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or back door opens. Prevents X-ray activation when open |
| Electromagnetic Safety Switch | Locks observation window when X-ray is active |
| Emergency Stop | Located near operation position - immediate power cutoff |
| Tube Protection | Software prevents leaving without proper X-ray tube closure |