| ब्रांड नाम: | WELLMAN |
| मॉडल संख्या: | एक्स-6000 |
| भुगतान की शर्तें: | टी/टी |
The X-6000 Automatic Inspection Equipment delivers advanced X-ray inspection capabilities for PCBA, BGA, and LED components with intuitive operation and high efficiency.
| X-ray Source | |
|---|---|
| Type | Closed, microfocus |
| Max Tube Voltage | 90kV |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm |
| Function | Auto preheat |
| Flat Panel Detector | |
|---|---|
| Effective Area | 130mm×130mm |
| Pixel Size | 85μm |
| Resolution | 1536×1536 |
| Frame Rate | 20fps |
| Table | |
|---|---|
| Size | 420mm×420mm |
| Detectable Area | 400mm×400mm |
| Max Load | 15kg |
| Equipment | |
|---|---|
| Magnification | Geometry 150X | System 1500X |
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1100mm (L) × 1000mm (W) × 1600mm (H) |
| Weight | 1000kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1300W |
| Industrial PC | Intel I5 CPU, 8G RAM, 240GB SSD |
| Displayer | 24" HDMI LCD |
Software Function
|
Function module |
Operation |
Keyboard and mouse can finish all operations |
|
X-ray tube control |
Using mouse to click the X button can turn on or off the X-ray. |
|
|
Status bar |
Indicates the interlock status, pre-heat status, and X-ray status by flashing alternately red and green. |
|
|
Image effect adjustment |
The brightness, contrast and gain of the image can be adjusted freely to achieve a satisfactory result. |
|
|
Product list |
Users can save the inspection parameters such as Z-axis position, and can directly call the parameters |
|
|
Navigation window |
the table will move to the place you click and display on the screen. |
|
|
Motion axis status |
Display real-time coordinates. |
|
|
Inspection result |
The measurement results (voids rate, distance, area, etc., set by users) display in order. |
|
|
Speed control |
The movement speed of each axis can be adjusted to slow, normal and fast. |
|
|
Voids rate measurement |
Automatic calculation |
Click on two points to determine a rectangle. |
|
Parameters adjustment |
Users can adjust the grayscale threshold, pixel and other parameters to get accurate results of automatic calculation. |
|
|
Add voids manually |
Users can draw a polygon or a free figure and calculate it as a void into the void rate. |
|
|
Save parameters |
Users can save parameters such as grayscale threshold and can directly call the parameters |
|
|
Other measurement function |
Distance |
Click the A and B points to set as the baseline, then click the C point to measure the vertical distance |
|
Distance rate |
It is mostly used to measure the soldering rate of the through-hole. |
|
|
Angle |
Click the A and B points to set as the baseline, then click the C point to measure the angle between the BA and BC rays. |
|
|
Radius |
Click three points to determine a circle and measure the circumference, area and radius. |
|
|
Perimeter |
click two points to determine a square, measure the length, width and area. |
|
|
Automatic inspection |
Manual setting |
Users can set any positions on the table as inspection points, the software will automatically inspect and save the picture. |
|
Array |
users only need to set two of the inspection points and the number of rows and columns |
|
|
Automatic identification |
For inspection points with obvious features, the software automatically identifies the positions, takes measurements, and saves the image. |