| نام تجاری: | WELLMAN |
| شماره مدل: | X-Ray X-6000 |
| موق: | 1 |
| شرایط پرداخت: | T/T |
| Type | Closed, microfocus |
|---|---|
| Max Tube Voltage | 90kV |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm |
| Function | Auto preheat |
| Effective Area | 130mm*130mm |
|---|---|
| Pixel Size | 85μm |
| Resolution | 1536*1536 |
| Frame Rate | 20fps |
| Size | 420mm*420mm |
|---|---|
| Detectable Area | 400mm*400mm |
| Max Load | 15kg |
| Magnification | Geometry 150X | System 1500X |
|---|---|
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1100mm (L) * 1000mm (W) * 1600mm (H) |
| Weight | 1000kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1300W |
| Industrial PC | Intel I5 CPU, 8G RAM, 240GB SSD |
| Displayer | 24" HDMI LCD |
| Radiation Leakage | No leakage, international standard: ≤1μSv/h |
|---|---|
| Lead Glass Observation Window | Transparent lead glass window shields radiation to observe the inner status |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or back door is opened |
| Electromagnetic Safety Switch | Locks when X-ray is on, preventing window opening |
| Emergency Stop | Located next to operation position for immediate power cutoff |
| Tube Protection | Prevents software exit without proper X-ray tube closure |
| Function Module | Operation |
|---|---|
| X-ray Tube Control | Mouse-click activation with real-time voltage/current display and adjustment |
| Status Bar | Visual indication of interlock, pre-heat, and X-ray status |
| Image Effect Adjustment | Adjustable brightness, contrast and gain for optimal imaging |
| Product List | Save and recall inspection parameters for efficiency |
| Navigation Window | Click-to-move table positioning with camera guidance |
| Motion Axis Status | Real-time coordinate display |
| Inspection Result | Organized display of measurement data with pass/fail indicators |
| Speed Control | Adjustable movement speed for each axis (slow, normal, fast) |
| Automatic Calculation | Rectangle-based solder ball analysis with void detection and NG/OK status |
|---|---|
| Parameters Adjustment | Customizable grayscale threshold, pixel, contrast, and size filtering |
| Add Voids Manually | Polygon or free-form void addition for comprehensive analysis |
| Save Parameters | Store and reuse measurement settings for consistent results |
| Distance | Vertical distance measurement from point to baseline |
|---|---|
| Distance Rate | Percentage ratio calculation for through-hole soldering rate |
| Angle | Angle measurement between defined rays |
| Radius | Circle measurement for round components with circumference and area |
| Perimeter | Square component measurement with length, width and area |
| Manual Setting | Custom inspection point positioning with automatic image capture |
|---|---|
| Array | Grid-based automatic inspection with row/column configuration |
| Automatic Identification | Feature-based position recognition with automated measurement |