| Brand Name: | HAMAMATSU |
| Model Number: | L9181-02 |
| MOQ: | 1 |
| Payment Terms: | T/T |
X-RAY SOURCE 130 kV MICROFOCUS X-RAY SOURCE L9181-02 delivers high-resolution imaging for industrial inspection applications.
Ideal for non-destructive inspection and X-ray CT applications including:
| Parameter | Description/Value | Unit |
|---|---|---|
| X-ray tube voltage setting range | 0 to 130 | kV |
| X-ray tube current setting range | 0 to 300 | μA |
| X-ray tube voltage operational range | 40 to 130 | kV |
| X-ray tube current operational range | 10 to 300 | μA |
| Maximum output | Small focus mode: 8 W Middle focus mode: 16 W Large focus mode: 39 W |
W |
| X-ray focal spot size (Nominal value) | Small focus mode: 8 (5μm at 4 W) Middle focus mode: 20 Large focus mode: 40 |
μm |
| X-ray output window material/Thickness | Beryllium/0.2 | mm |
| X-ray beam angle | Approx.45 | degree |
| Focus to object distance (FOD) | Approx.13 | mm |
| Target material | Tungsten | -- |
| Weight | Approx.10.5 | kg |
| Communication method | Interface: RS-232C (9-pin D-sub connector) | -- |
| Parameter | Description/Value | Unit |
|---|---|---|
| Input voltage (DC) | +24 (+2.4,-0) | V |
| Power consumption | Less than 120 | W |
| Read output | Continuous rating | -- |
| Operating ambient temperature | +10 to +40 | ℃ |
| Storage ambient temperature | 0 to +50 | ℃ |
| Operating and storage humidity | 20 to 85 (No condensation) | % |
| Parameter | Description | Unit |
|---|---|---|
| RoHS Directive | EN 50581 Category 9 | -- |
| EMC | IEC/EN 61326-1 Emission limits: CISPR 11 Group 1 Class A Immunity requirements: Table 2 |
-- |
| Parameter | Description | Unit |
|---|---|---|
| Applicable PC | PC/AT compatible | -- |
| Applicable OS | Windows® XP, 7 | -- |
| Interface | RS-232C | -- |
Note:
① See the graph of the X-ray tube voltage/current operation range.
② Reference value: With 50% of maximum X-ray emission.
③ This weight includes the accessories of approx. 0.25 kg.
④ The control software is provided as sample software for MFX operation. The performance of the software is not guaranteed.