Hamamatsu 150KV Microfocus X-Ray Source 5μm Focal Spot Industrial NDT
HAMAMATSU 150 kV MICROFOCUS X-RAY SOURCE L12161-07
FEATURES
  • Focal spot size: 5 μm (at 4 W) - The sealed type X-ray tube offers sharp and clear X-ray images even at high magnification
  • High power: Maximum output 75 W
  • External control via RS-232C interface
  • High speed ramping-up - Up to 3 times faster than conventional 150 kV microfocus X-ray sources
  • No high voltage cable connection required - High voltage power supply is integrated
APPLICATIONS
  • Non-destructive inspection
  • X-ray CT
Applicable objects
  • Semiconductor device
  • Electronic component
  • Printed circuit board
  • Ceramic
  • Plastic component
  • Die casting
  • Metal component
SPECIFICATIONS
GENERAL
Parameter Description/Value Unit
X-ray tube voltage setting range 0 to 150 kV
X-ray tube current setting range 0 to 500 mA
X-ray tube voltage operational range 1 40 to 150 kV
X-ray tube current operational range 1 10 to 500 mA
Maximum output Small Focus Mode: 10 W
Middle Focus Mode: 30 W
Large Focus Mode: 75 W
W
X-ray focal spot size (Nominal value) Small Focus Mode: 7 (5 mm at 4 W)
Middle Focus Mode: 20
Large Focus Mode: 50
mm
X-ray beam angle 2 Approx. 43 degree
Focus to object distance (FOD) Approx. 17 mm
Rated output Continuous rating --
Communication method Interface: RS-232C (9-pin D-sub connector) --
X-RAY TUBE UNIT
Parameter Description/Value Unit
X-ray output window material / Thickness Beryllium / 0.2 mm
Target material Tungsten --
Operating ambient temperature +10 to +40 °C
Storage ambient temperature 0 to +50 °C
Operating and storage humidity 20 to 85 (No condensation) %
Weight Approx. 13.5 kg
X-RAY CONTROL UNIT
Parameter Description / Value Unit
Input voltage (AC) Single phase 100 to 240 (50 Hz / 60 Hz) V
Power consumption Less than 220 W
Operating ambient temperature +10 to +40 °C
Storage ambient temperature 0 to +50 °C
Operating and storage humidity 20 to 85 (No condensation) %
Weight 3 Approx. 6 kg
REGULATION AND STANDARDS
Parameter Description Unit
RoHS directive EN 50581 Category 9 --
EMC IEC/EN 61326-1 Emission limits: CISPR 11 Group 1 Class A Immunity requirements: Table 2 --
Safety IEC/EN 61010-1 --
CONTROL SOFTWARE 4
Parameter Description Unit
Applicable PC PC / AT compatible --
Applicable OS Windows® XP, 7 --
Interface RS-232C interface --
NOTE:
1. See the graph of the X-ray tube voltage / current operation range.
2. Reference value: With 50% of maximum X-ray emission.
3. This weight includes the accessories of approx. 1.5 kg.
4. The control software is provided as sample software for the purpose of MFX operation. The performance of the software is not guaranteed.
150kV Hamamatsu X Ray Source 5μM Spot Industrial NDT High Power 75W 0 150kV Hamamatsu X Ray Source 5μM Spot Industrial NDT High Power 75W 1 150kV Hamamatsu X Ray Source 5μM Spot Industrial NDT High Power 75W 2 150kV Hamamatsu X Ray Source 5μM Spot Industrial NDT High Power 75W 3 150kV Hamamatsu X Ray Source 5μM Spot Industrial NDT High Power 75W 4