| Nombre De La Marca: | WELLMAN |
| Número De Modelo: | X6800 |
| Moq: | 1 |
| Términos De Pago: | T/T |
| Component | Parameter | Specification |
|---|---|---|
| X-ray Source | Type | Closed, microfocus |
| Max Tube Voltage | 90kV | |
| Max Tube Current | 200μA | |
| Focal Spot Size | 5μm | |
| Flat Panel Detector | Effective Area | 130mm×130mm |
| Pixel Size | 85μm | |
| Resolution | 1536×1536 | |
| Frame Rate | 20fps | |
| Tiltable Angle | 60° | |
| Table | Size | 530mm×530mm |
| Detectable Area | 500mm×500mm | |
| Max Load | 10kg | |
| Equipment | Magnification | Geometry 200X | System 1500X |
| Inspection Speed | Max 3.0s/point | |
| Dimensions | 1360mm (L)×1365mm (W)×1730mm (H) | |
| Weight | 1200kg | |
| Power Supply | AC110-220V 50/60HZ | |
| Max Power | 1500W | |
| Industrial PC | I5 CPU, 8G RAM, 500GB SSD | |
| Safety Features | Radiation Leakage | No leakage, international standard: ≤1μSv/h |
| Lead Glass Observation Window | Transparent lead glass window shields radiation for internal status observation | |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or back door is opened | |
| Electromagnetic Safety Switch | Locks when X-ray is on, preventing window opening | |
| Emergency Stop | Located near operation position for immediate power cutoff | |
| Tube Protection | Software prevents leaving without closing X-ray tube |
| Function | Description | Application |
|---|---|---|
| Voids Rate Measurement | Automatic calculation of voids rate, solder ball area, circumference, and dimensions with NG/OK indication | Solder joint quality assessment |
| Parameter Adjustment | Customizable grayscale threshold, pixel, contrast, and size filtering parameters | Optimizing measurement accuracy |
| Manual Void Addition | Polygon or free-form drawing to include additional voids in calculations | Complex defect analysis |
| Parameter Saving | Save and recall measurement parameters for consistent results | Batch inspection efficiency |
| Distance Measurement | Point-to-baseline vertical distance calculation | Component positioning verification |
| Distance Rate | Percentage ratio calculation for through-hole soldering rate | Plated through-hole inspection |
| Angle Measurement | Angle calculation between defined rays | Component alignment verification |
| Radius Measurement | Three-point circle determination with circumference, area, and radius calculation | Round component inspection |
| Perimeter Measurement | Square component measurement for length, width, and area | Rectangular component verification |