| Brand Name: | WELLMAN |
| Model Number: | X-ray X8800 |
| Payment Terms: | T/T |
| Focal spot size | 1μm |
| Type | Open, microfocus |
| Max tube voltage | 160kV |
| Max tube current | 500μA |
| Target power | 15W |
| Tube power | 65W |
| Tiltable angle | 60° |
| Rotation angle | 360° |
| Pixel size | 49.5μm |
| Resolution | 1536*1536 |
| Frame rate | 20fps |
| Max load | 10kg |
| Size | 400mm*400mm |
| Detectable area | 400mm*400mm |
| Geometry Magnification | 2500X |
| Inspection speed | Max 3.0s/point |
| Dimensions | 1550mm (L) * 1600mm (W) * 1700mm (H) |
| Weight | 1800kg |
| Power supply | AC110-220V 50/60HZ |
| Max power | 1800W |
| Industrial PC | I7 CPU, 16G RAM, 240GB SSD+1TB HDD |
| Displayer | 24" HDMI LCD |
| Radiation leakage | No leakage, international standard: ≤1μSv/h |
| Lead glass observation window | Transparent lead glass window shields radiation to observe the inner status |
| Electromagnetic safety switch | Lock once the X-ray is on, users can't open the observation window |
| Emergency stop | Next to the operation position, press to power off |
| Tube protection | User can't leave the software if you don't close the X-ray tube |
| Window and back door safety interlock | Once users open the window or back door, X-ray tube will power off immediately. When the window or back door is open, users can't turn on the X-ray |
| Function module | Keyboard and mouse can finish all operations |
| X-ray tube control | Using mouse to click the X button can turn on or off the X-ray |
| Status bar | Indicates the interlock status, pre-heat status, and X-ray status by flashing alternately red and green |
| Image effect adjustment | The brightness, contrast and gain of the image can be adjusted freely to achieve a satisfactory result |
| Product list | Users can save the inspection parameters and can directly call the parameters |
| Navigation window | The table will move to the place you click and display on the screen |
| Motion axis status | Display real-time coordinates |
| Inspection result | The measurement results (voids rate, distance, area, etc., set by users) display in order |
| Speed control | Slow, normal and fast |
| Automatic calculation | The software automatically finds and measures the edge of the solder ball in the rectangle, the pad and the internal voids, and can get the data of the voids rate, the area of the solder ball, the circumference, the biggest void's rate, the length and the width, and indicates NG or OK by red and green |
| Parameters adjustment | Users can adjust the grayscale threshold, pixel, contrast, size filtering and other parameters |
| Add voids manually | Draw a polygon or a free figure and calculate it as a void into the void rate |
| Save parameters | Users can save parameters and can directly call the parameters |
| Distance | Click the A and B points to set as the baseline, then click the C point to measure the vertical distance from the C point to the baseline |
| Distance rate | Divide the vertical distance from the D point to baseline by the vertical distance of the C point, to obtain the percentage ratio of the vertical distance of D to C |
| Angle | Click the A and B points to set as the baseline, then click the C point to measure the angle between the BA and BC rays |
| Radius | Click three points to determine a circle and measure the circumference, area and radius |
| Perimeter | Click two points to determine a square, measure the length, width and area |
| Manual setting | Users can set any positions on the table as inspection points, the software will automatically inspect and save the picture |
| Array | For the regular inspection points, users only need to set two of the inspection points and the number of rows and columns, the software will automatically inspect each point and save pictures |
| Automatic identification | For inspection points with obvious features, the software automatically identifies the positions, takes measurements, and saves the image |