| Brand Name: | WELLMAN |
| Model Number: | X-ray X8800 |
| Payment Terms: | T/T |
| X-ray Source | ||
| Type | Open, microfocus | |
| Max tube voltage | 160kV | |
| Max tube current | 500μA | |
| Target power | 15W | |
| Tube power | 65W | |
| Focal spot size | 1μm | |
| Flat Panel Detector | ||
| Effective area | 130mm×130mm | |
| Pixel size | 49.5μm | |
| Resolution | 1536×1536 | |
| Frame rate | 20fps | |
| Tiltable angle | 60° | |
| Rotation angle | 360° | |
| Table | ||
| Size | 400mm×400mm | |
| Detectable area | 400mm×400mm | |
| Max load | 10kg | |
| Equipment | ||
| Geometry Magnification | 2500X | |
| Inspection speed | Max 3.0s/point | |
| Dimensions | 1550mm (L) × 1600mm (W) × 1700mm (H) | |
| Weight | 1800kg | |
| Power supply | AC110-220V 50/60HZ | |
| Max power | 1800W | |
| Industrial PC | I7 CPU, 16G RAM, 240GB SSD+1TB HDD | |
| Display | 24" HDMI LCD | |
| Safety Features | ||
| Radiation leakage | No leakage, international standard: ≤1μSv/h | |
| Lead glass observation window | Transparent lead glass window shields radiation to observe the inner status | |
| Window and back door safety interlock | X-ray tube powers off immediately when window or back door is opened | |
| Electromagnetic safety switch | Locks when X-ray is on, preventing observation window opening | |
| Emergency stop | Located next to operation position, press to power off | |
| Tube protection | Software prevents user from leaving without closing X-ray tube | |
| Function Module | |
| Operation | Keyboard and mouse can finish all operations |
| X-ray tube control | Mouse-click X button to turn on/off X-ray. Real-time voltage and current display with adjustable controls |
| Status bar | Indicates interlock status, pre-heat status, and X-ray status by flashing alternately red and green |
| Image effect adjustment | Brightness, contrast and gain adjustable for optimal image quality |
| Product list | Save inspection parameters for efficient recall when inspecting same products |
| Navigation window | Click anywhere in table photo to move table to selected position |
| Motion axis status | Display real-time coordinates |
| Inspection result | Measurement results (voids rate, distance, area, etc.) display in order |
| Speed control | Movement speed of each axis adjustable to slow, normal and fast |
| Voids Rate Measurement | |
| Automatic calculation | Click two points to define rectangle for automatic solder ball edge detection and voids measurement |
| Parameters adjustment | Adjust grayscale threshold, pixel, contrast, size filtering for accurate results |
| Add voids manually | Draw polygon or free figure to calculate as void into void rate |
| Save parameters | Save measurement parameters for efficient recall on same products |
| Other Measurement Functions | |
| Distance | Measure vertical distance from point to baseline |
| Distance rate | Calculate percentage ratio for through-hole soldering rate measurement |
| Angle | Measure angle between rays |
| Radius | Measure round components circumference, area and radius |
| Perimeter | Measure square components length, width and area |
| Automatic Inspection | |
| Manual setting | Set any positions as inspection points for automatic inspection and image saving |
| Array | Automatic inspection of regular points using row and column configuration |
| Automatic identification | Software automatically identifies positions with obvious features for measurement |