| Brand Name: | WELLMAN |
| Model Number: | X-6800 |
| MOQ: | 1 |
| Payment Terms: | T/T |
| Supply Ability: | Worldwide supply |
| X-ray Source | |
|---|---|
| Type | Closed, microfocus |
| Max Tube Voltage | 90kV (110kV, 130kV optional) |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm (4μm, 2μm optional) |
| Function | Auto preheat |
| Flat Panel Detector | |
| Effective Area | 130mm×130mm |
| Pixel Size | 85μm |
| Resolution | 1536×1536 |
| Frame Rate | 20fps |
| Tiltable Angle | 60° |
| Table | |
| Size | 530mm×530mm |
| Detectable Area | 500mm×500mm |
| Max Load | 10kg |
| Equipment | |
| Magnification | Geometry 200X | System 1500X |
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1360mm (L) × 1365mm (W) × 1730mm (H) |
| Weight | 1200kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1500W |
| Industrial PC | I5 CPU, 8G RAM, 500GB SSD |
| Display | 24" HDMI LCD |
| Safety Features | |
| Radiation Leakage | No leakage, international standard: ≤1μSv/h |
| Lead Glass Observation Window | Transparent lead glass window shields radiation to observe inner status |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or back door is opened |
| Electromagnetic Safety Switch | Locks when X-ray is on, preventing window opening |
| Emergency Stop | Located next to operation position for immediate power off |
| Tube Protection | Software prevents leaving without closing X-ray tube |
| Function Module | Operation |
|---|---|
| Operation Method | Keyboard and mouse complete all operations |
| X-ray Tube Control | Mouse click on X button to turn on/off X-ray |
| Status Bar | Indicates interlock status, pre-heat status, and X-ray status with red/green flashing |
| Image Effect Adjustment | Freely adjust brightness, contrast and gain |
| Product List | Save inspection parameters for same product inspection |
| Navigation Window | Table moves to clicked position and displays on screen |
| Motion Axis Status | Display real-time coordinates |
| Inspection Result | Measurement results display in order (voids rate, distance, area, etc.) |
| Speed Control | Adjust movement speed of each axis to slow, normal or fast |
| Voids Rate Measurement | |
| Automatic Calculation | Click two points to determine rectangle for calculation |
| Parameters Adjustment | Adjust grayscale threshold, pixel, contrast, size filtering parameters |
| Add Voids Manually | Draw polygon or free figure to calculate as void |
| Save Parameters | Save grayscale threshold, pixel, contrast, size filtering parameters |
| Other Measurement Functions | |
| Distance | Click A and B points for baseline, then C point for vertical distance measurement |
| Distance Rate | Calculate percentage ratio of vertical distances |
| Angle | Measure angle between BA and BC rays |
| Radius | Click three points to determine circle and measure circumference, area, radius |
| Perimeter | Measure square components length, width and area |
| Automatic Inspection | |
| Manual Setting | Set any positions as inspection points for automatic inspection and image saving |
| Array | Set inspection points with rows and columns for automatic inspection |
| Automatic Identification | Software automatically identifies positions with obvious features for measurement |