| Brand Name: | WELLMAN |
| Model Number: | X-6000 |
| MOQ: | 1 |
| Payment Terms: | T/T |
| Supply Ability: | Worldwide supply |
| Category | Specifications |
|---|---|
| X-ray Source | Closed microfocus, 90kV max tube voltage, 200μA max tube current, 5μm focal spot, auto preheat |
| Flat Panel Detector | 130mm×130mm effective area, 85μm pixel size, 1536×1536 resolution, 20fps frame rate |
| Table | 420mm×420mm size, 400mm×400mm detectable area, 15kg max load |
| Equipment | 150X geometry magnification, 1500X system magnification, max 3.0s/point inspection speed |
| Dimensions & Weight | 1100mm(L)×1000mm(W)×1600mm(H), 1000kg |
| Power Supply | AC110-220V 50/60HZ, 1300W max power |
| Configuration | Intel I5 CPU, 8G RAM, 240GB SSD, 24" HDMI LCD display |
| Radiation leakage | No leakage, international standard: ≤1μSv/h |
| Function module | Operation |
|---|---|
| X-ray tube control | Using Keyboard and mouse |
| Status bar | Indicates the interlock status, pre-heat status, and X-ray status by flashing alternately red and green |
| Image effect adjustment | The brightness, contrast and gain of the image can be adjusted freely |
| Product list | Users can save the inspection parameters such as Z-axis position, brightness, contrast and gain... |
| Navigation window | The table will move to the place you click and display on the screen. |
| Motion axis status | Display real-time coordinates. |
| Inspection result | The measurement results (voids rate, distance, area, etc., set by users) display in order. |
| Speed control | The movement speed of each axis can be adjusted (slow, normal and fast) |
| Automatic calculation | Click on two points to determine a rectangle. |
| Parameters adjustment | Users can adjust the grayscale threshold, pixel, contrast, size filtering and other parameters. |
| Add voids manually | Users can draw a polygon or a free figure and calculate it as a void into the void rate. |
| Save parameters | Users can save parameters and can directly save the parameters. |
| Distance | Click the A and B points to set as the baseline, then click the C point to measure the vertical distance from the C point to the baseline. |
| Distance rate | It is mostly used to measure the soldering rate of the through-hole. |
| Angle | Click the A and B points to set as the baseline, then click the C point to measure the angle between the BA and BC rays. |
| Radius | Click three points to determine a circle and measure the circumference, area and radius. |
| Perimeter | Click two points to determine a square, measure the length, width and area. |
| Manual setting | Users can set any positions on the table as inspection points, the software will automatically inspect and save the picture. |
| Array | Set two of the inspection points and the number of rows and columns, the software will automatically inspect each point and save pictures. |
| Automatic identification | The software automatically identifies the positions, takes measurements, and saves the image. |