| Brand Name: | WELLMAN |
| Model Number: | X-6800 |
| MOQ: | 1 |
| Payment Terms: | T/T |
| Supply Ability: | Worldwide supply |
| X-ray Source | ||
|---|---|---|
| Type | Closed, microfocus | |
| Max Tube Voltage | 90kV (110kV, 130kV optional) | |
| Max Tube Current | 200μA | |
| Focal Spot Size | 5μm (4μm, 2μm optional) | |
| Function | Auto preheat | |
| Flat Panel Detector | ||
| Effective Area | 130mm×130mm | |
| Pixel Size | 85μm | |
| Resolution | 1536×1536 | |
| Frame Rate | 20fps | |
| Tiltable Angle | 60° | |
| Table | ||
| Size | 530mm×530mm | |
| Detectable Area | 500mm×500mm | |
| Max Load | 10kg | |
| Equipment | ||
| Magnification | Geometry 200X | System 1500X |
| Inspection Speed | Max 3.0s/point | |
| Dimensions | 1360mm (L) × 1365mm (W) × 1730mm (H) | |
| Weight | 1200kg | |
| Power Supply | AC110-220V 50/60HZ | |
| Max Power | 1500W | |
| Industrial PC | I5 CPU, 8G RAM, 500GB SSD | |
| Displayer | 24" HDMI LCD | |
| Safety Features | ||
| Radiation Leakage | No leakage, international standard: ≤1μSv/h | |
| Lead Glass Observation Window | Transparent lead glass window shields radiation | |
| Window and Back Door Safety Interlock | X-ray tube powers off when opened | |
| Electromagnetic Safety Switch | Locks when X-ray is on | |
| Emergency Stop | Located next to operation position | |
| Tube Protection | Software prevents leaving without closing X-ray tube | |
| Function Module | Operation |
|---|---|
| X-ray Tube Control | Mouse click to turn on/off X-ray with real-time voltage/current display |
| Status Bar | Displays interlock status, pre-heat status, and X-ray status |
| Image Effect Adjustment | Adjust brightness, contrast and gain for optimal results |
| Product List | Save and recall inspection parameters for efficiency |
| Navigation Window | Click anywhere in photo to move table to position |
| Motion Axis Status | Display real-time coordinates |
| Inspection Result | Display measurement results in order |
| Speed Control | Adjust movement speed for each axis |
| Voids Rate Measurement | |
| Automatic Calculation | Click two points to determine rectangle for automatic solder ball analysis |
| Parameters Adjustment | Adjust grayscale threshold, pixel, contrast, and size filtering |
| Add Voids Manually | Draw polygons or free figures to calculate as voids |
| Save Parameters | Save and recall parameters for same product inspection |
| Other Measurement Functions | |
| Distance | Measure vertical distance from point to baseline |
| Distance Rate | Measure soldering rate of through-hole components |
| Angle | Measure angle between rays |
| Radius | Measure round components using three-point circle determination |
| Perimeter | Measure square components with two-point determination |
| Automatic Inspection | |
| Manual Setting | Set any positions as inspection points with automatic inspection |
| Array | Automatic inspection for regular points using row/column configuration |
| Automatic Identification | Software automatically identifies positions with obvious features |