| Nome da marca: | WELLMAN |
| Número do modelo: | X-6000 |
| Termos de pagamento: | T/T |
| Type | Closed, microfocus |
|---|---|
| Max Tube Voltage | 90kV |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm |
| Function | Auto preheat |
| Effective Area | 130mm×130mm |
|---|---|
| Pixel Size | 85μm |
| Resolution | 1536×1536 |
| Frame Rate | 20fps |
| Size | 420mm×420mm |
|---|---|
| Detectable Area | 400mm×400mm |
| Max Load | 15kg |
| Magnification | Geometry 150X | System 1500X |
|---|---|
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1100mm (L) × 1000mm (W) × 1600mm (H) |
| Weight | 1000kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1300W |
| Industrial PC | Intel I5 CPU, 8G RAM, 240GB SSD |
| Displayer | 24" HDMI LCD |
| Radiation Leakage | No leakage |
|---|---|
| Lead Glass Observation Window | Transparent lead glass window shields radiation to observe internal status |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or door opens |
| Electromagnetic Safety Switch | Locks when X-ray is on, preventing window opening |
| Emergency Stop | Located next to operation position for immediate power cutoff |
| Tube Protection | Software prevents leaving without closing X-ray tube |
| Function module | Operation | Using Keyboard and mouse |
|---|---|---|
| X-ray tube control | Using mouse to click the X button | |
| Status bar | Indicates the interlock status, pre-heat status, and X-ray status by flashing alternately red and green | |
| Image effect adjustment | The brightness, contrast and gain of the image can be adjusted freely | |
| Product list | Users can save the inspection parameters such as Z-axis position, brightness, contrast and gain... | |
| Navigation window | The table will move to the place you click and display on the screen. | |
| Motion axis status | Display real-time coordinates. | |
| Inspection result | The measurement results (voids rate, distance, area, etc., set by users) display in order. | |
| Speed control | The movement speed of each axis can be adjusted (slow, normal and fast) | |
| Voids rate measurement | Automatic calculation | Click on two points to determine a rectangle. |
| Parameters adjustment | Users can adjust the grayscale threshold, pixel, contrast, size filtering and other parameters. | |
| Add voids manually | Users can draw a polygon or a free figure and calculate it as a void into the void rate. | |
| Save parameters | Users can save parameters and can directly save the parameters. | |
| Other measurement function | Distance | Click the A and B points to set as the baseline, then click the C point to measure the vertical distance from the C point to the baseline. |
| Distance rate | It is mostly used to measure the soldering rate of the through-hole. | |
| Angle | Click the A and B points to set as the baseline, then click the C point to measure the angle between the BA and BC rays. | |
| Radius | Click three points to determine a circle and measure the circumference, area and radius. | |
| Perimeter | Click two points to determine a square, measure the length, width and area. | |
| Automatic inspection | Manual setting | Users can set any positions on the table as inspection points, the software will automatically inspect and save the picture. |
| Array | Set two of the inspection points and the number of rows and columns, the software will automatically inspect each point and save pictures. | |
| Automatic identification | The software automatically identifies the positions, takes measurements, and saves the image. |