| Markenname: | WELLMAN |
| Modellnummer: | X-6000 |
| Zahlungsbedingungen: | T/T |
10000 Hours Lifetime
0 Leakage Radiation
Maintenance-free
13×13 cm high-definition large-area
Tiltable 30°/60°/180°(optional)
420×420mm table with 15KG load capacity
only 2 hours to train
(No training fees)
The table will move to where you click and display on the screen.
3-axes coordination
Speed (slow, normal fast)
| X-ray Source | |
|---|---|
| Type | Closed, microfocus |
| Max Tube Voltage | 90kV |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm |
| Function | Auto preheat |
| Flat Panel Detector | |
|---|---|
| Effective Area | 130mm×130mm |
| Pixel Size | 85μm |
| Resolution | 1536×1536 |
| Frame Rate | 20fps |
| Table | |
|---|---|
| Size | 420mm×420mm |
| Detectable Area | 400mm×400mm |
| Max Load | 15kg |
| Equipment | |
|---|---|
| Magnification | Geometry 150X | System 1500X |
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1100mm (L) × 1000mm (W) × 1600mm (H) |
| Weight | 1000kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1300W |
| Industrial PC | Intel I5 CPU, 8G RAM, 240GB SSD |
| Displayer | 24" HDMI LCD |
Using mouse to click the X button can turn on or off the X-ray.
Indicates the interlock status, pre-heat status, and X-ray status by flashing alternately red and green.
The brightness, contrast and gain of the image can be adjusted freely
Users can save the inspection parameters and can directly call the parameters.
The table will move to the place you click and display on the screen.
Display real-time coordinates.
The measurement results (voids rate, distance, area, etc., set by users) display in order.
The movement speed of each axis can be adjusted to slow, normal and fast.
Automatic calculation - Click on two points to determine a rectangle.
Users can adjust the grayscale threshold, pixel and other parameters
Users can draw a polygon or a free figure and calculate it as a void into the void rate.
Users can save parameters such as grayscale threshold and can directly call the parameters.
| Function | Description |
|---|---|
| Distance | Click the A and B points to set as the baseline, then click the C point to measure the vertical distance |
| Distance Rate | Mostly used to measure the soldering rate of the through-hole |
| Angle | Click the A and B points to set as the baseline, then click the C point to measure the angle between the BA and BC rays |
| Radius | Click three points to determine a circle and measure the circumference, area and radius |
| Perimeter | Click two points to determine a square, measure the length, width and area |
| Mode | Description |
|---|---|
| Manual Setting | Users can set any positions on the table as inspection points, the software will automatically inspect and save the picture |
| Array | Users only need to set two of the inspection points and the number of rows and columns |
| Automatic Identification | For inspection points with obvious features, the software automatically identifies the positions, takes measurements, and saves the image |